{"product_id":"heatstrip-flush-mount-enclosure-for-heatstrip-®-intense","title":"Heatstrip Flush Mount Enclosure for HEATSTRIP ® Intense","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe Flush Mount Enclosure is designed to provide a neat ceiling installation for HEATSTRIP Intense heaters. It is supplied as a one-piece enclosure and can be installed with plaster or timber-lined ceiling materials. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTwo enclosure sizes are specified for the applicable heater models, with different cutout dimensions, overall dimensions, and weights. A minimum 200 mm clearance behind the enclosure is required. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush Ceiling Installation:\u003c\/strong\u003e Designed for neatly installing the heater into a ceiling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne-Piece Construction:\u003c\/strong\u003e Supplied as a one-piece unit for mounting an individual heater.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCeiling Material Compatibility:\u003c\/strong\u003e Suitable for plaster or timber-lined ceiling materials.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo Size Options:\u003c\/strong\u003e Available for the 2200W and 3200W heater models.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowder-Coated Construction:\u003c\/strong\u003e Manufactured from powder-coated steel with a black or white fascia.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Rear Clearance:\u003c\/strong\u003e A minimum clearance of 200 mm behind the enclosure must be provided.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation Openings:\u003c\/strong\u003e Ventilation openings must remain unobstructed to allow air movement into the ceiling space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation Clearances:\u003c\/strong\u003e A minimum distance of 200 mm from the back of the enclosure to building material, 50 mm from the sides to support structures, and 200 mm between adjacent enclosures is required.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Preparation:\u003c\/strong\u003e The installation area must have the correct-size opening and secure mounting points before the enclosure is installed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Hardware:\u003c\/strong\u003e Screws for fixing the enclosure into battens are not included. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable Model:\u003c\/strong\u003e THB2200BA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHole Cutout Dimensions:\u003c\/strong\u003e 1012(L) x 201(W) mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Dimensions:\u003c\/strong\u003e 1012(L) x 201(W) x 201(D) mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuitable Model:\u003c\/strong\u003e THB3200BA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHole Cutout Dimensions:\u003c\/strong\u003e 1152(L) x 205(W) mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Dimensions:\u003c\/strong\u003e 1208(L) x 258(W) x 201(D) mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 5 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Powder-coated steel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFascia:\u003c\/strong\u003e Black fascia or white fascia \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSize Guide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTHBAC-001:\u003c\/strong\u003e Overall dimension A: 1068 mm; B: 1012 mm; C: 1012 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTHYAC-051:\u003c\/strong\u003e Overall dimension A: 1208 mm; B: 1152 mm; C: 1148 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdeal Mounting Height:\u003c\/strong\u003e 2.3m - 2.5m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Ceiling Height:\u003c\/strong\u003e 2.8m in an outdoor enclosed environment \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible With:\u003c\/strong\u003e THB2200BA and THB3200BA heaters, according to the applicable enclosure size. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIncluded\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush Mount Enclosure:\u003c\/strong\u003e One-piece enclosure suitable for mounting an individual heater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0830\/0855\/3185\/files\/THB-BA-Flush-Mount-Encloser-Manual-31.05.23-V1_2.pdf?v=1789046289\" style=\"padding: 9px 18px; border: 2px solid #000000; border-radius: 30px; color: #000000; text-decoration: none; font-weight: bold;\" target=\"_blank\"\u003eProduct Manual\u003c\/a\u003e\u003c\/p\u003e","brand":"Heatstrip","offers":[{"title":"THB2200BA","offer_id":49078996107489,"sku":"THBAC-001","price":924.0,"currency_code":"USD","in_stock":true},{"title":"THB3200BA","offer_id":49078996140257,"sku":"THYAC-051","price":838.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0830\/0855\/3185\/files\/HEATSPRING_3.png?v=1789046617","url":"https:\/\/everfieldliving.com\/products\/heatstrip-flush-mount-enclosure-for-heatstrip-%c2%ae-intense","provider":"Everfield Living","version":"1.0","type":"link"}